Home Air Conditioning Equipment & Systems Room Based Cooling Solutions
 

Stulz Computer Room Air Conditioning (CRAC) CyberAiR Room Cooling Solution

Stulz CRAC CyberAiR Cooling SolutionThe CyberAiR 2 precision air-conditioning system with DFC conditions the air in large computer and equipment rooms with a heat load of over 20 kilowatts up to 60 % more economically than conventional compressor cooling systems.

CyberAiR 2 is the world’s first precision air-conditioning system that considers heat load in computer rooms and seasonally varying ambient temperatures. It automatically selects the optimal operation mode for each case. In cool weather, the optional DFC automatic air-conditioning technology makes use of thrifty dynamic free cooling with outside air. Energy-intensive compressor cooling (DX) is only switched on when absolutely necessary. For this purpose, all units are equipped with speed-controlled EC fans and electronic expansion valves.

In addition to the DFC version described above, STULZ also offers the CyberAiR 2 series in the versions A, G, GE, ACW, GCW, CW and CW2. CyberAiR 2 units are available in six sizes. They require floor space 1000 mm to 2900 mm wide and only 890 mm deep. And the planner has a choice of three coolants - R407C, R410A or R134a.

Features & Benefits

Features Benefits

Control by microprocessor

Each unit has its own electronic controller. The C7000 microprocessor controls all active components.

Seven cooling systems

From a choice of seven cooling systems, data center operators will find the optimum balance between investment, running costs, and energy efficiency. All systems are available as both up-flow and down-flow versions.

Save space and energy

Units are produced both as a space-saving standard version and an energy-optimized low-energy version

Three different refrigerants

In addition to water as the cooling medium, the devices can run with three different refrigerants R407C, R410A, and high temperature refrigerant R134a.

Back to the Top

CyberAiR 2 DX and Dual-Fluid Units, single-circuit

Cooling capacity 18 kW to 54 kW
Cooling systems A/G/ACW/GCW
Direction of air Down-flow / up-flow
Sizes 1-3

CyberAiR 2 DX and Dual-Fluid Units, dual-circuit

Cooling capacity 40 kW to 105 kW
Cooling systems A/G/ACW/GCW
Direction of air Down-flow / up-flow
Sizes 3-5

CyberAiR 2 LowNoise DX and GE Units, single-circuit

Cooling capacity 18 kW to 54 kW
Cooling systems A/G/GE
Direction of air Down-flow / up-flow
Sizes 2-4

CyberAiR 2 LowNoise DX Units, dual-circuit

Cooling capacity 41 kW to 73 kW
Cooling systems A/G
Direction of air Down-flow / up-flow
Sizes 4-5

Dimensions (WxHxD in mm)

Size 1 1000 x 1980 x 890
Size 2 1400 x 1980 x 890
Size 3 1750 x 1980 x 890
Size 4 2150 x 1980 x 890
Size 5 2550 x 1980 x 890
Size 7 2900 x 1980 x 890

To learn more about PTS consulting services to support Air Conditioning Equipment & Systems deployments and support, contact us or visit:



Back to the Top



Loading


Visit PTS on Facebook Follow PTS on Twitter View PTS' YouTube Channel Connect with PTS on LinkedIn Read PTS' Blog
Share
Virtualization Savings Calculator Sign Up for PTS Newsletters Data Center Maintenance Management Software (DCMMS) Rack Management Platform (RaMP) from No Limits Software Considering Data Center Migration? PTS White Paper Library Data Center Education and Training
** SPECIAL **
CFD SERVICES
COMPUTER ROOM
SERVICES
SERVER ROOM &
NETWORK ROOM
SERVICES
DATA CENTER
INDUSTRY LINKS
PTS DATA CENTER PROJECT IMAGE GALLERY
PTS Image Gallery
SUPPORT
1.866.PTS.DCS1
1.866.787.3271
info@ptsdcs.com
PTS Data Center Solutions, Inc. 568 Commerce Street, Franklin Lakes, NJ 07417
Toll Free: 1.866.PTS.DCS1   Tel: 201.337.3833   Fax: 201.337.4722   Email: info@ptsdcs.com
 
Data Center News & Information | Data Center Consulting | Data Center Design & Engineering | Data Center Project Management
Data Center Construction | Data Center Solutions | Data Center Monitoring & Control | Data Center Operations & Maintenance
 
Request Info About Us Contact Us Site Map
© PTS Data Center Solutions, Inc. All rights reserved.