APC InfraStruxure InRow SC DX Air Cooled High Density Data Center Cooling Solution

InRow SC DX, 300mm, Air Cooled, Self-contained 200-240V 60Hz
InRow SC DX, 300mm, Air Cooled,
Self-contained 200-240V 60Hz

InfraStruxure InRow SC DX Air Cooled Data Center Cooling Solutions are modular direct expansion (DX) air conditioning units. They are one-half the width of a standard enclosure, and can be placed in a data-center row. They provide full management capabilities over a network using Telnet, Secure Shell (SSH), HTTP, HTTPS, FTP, Secure Copy (SCP), Modbus and SNMP. The InRow SC provides the following features:

  • Active response controls: Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Easy to install: Innovative design allows for fast, easy installation by almost anybody.
  • Fault-tolerant fan system: In the event of a fan failure, the remaining fan(s) will continue to operate.
  • Horizontal airflow pattern: Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.
  • Scalable Architecture: Cascade multiple KVM switches for a modular solution that supports multiple platforms, improving flexibility and simplifying future expansion. Please see the user's manual for specific cascading capabilities.
  • Dry contact output: Provides remote notification of failures when used with APC environmental monitoring unit or system.
  • Field replaceable components: Fans and electronics module can be readily replaced without uninstalling the unit.

Features & Benefits

Features Benefits

Availability

Predictable cooling

Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Rack Inlet Temperature Control

Reduces the risk of hot spots at the rack level.

Active response controls

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Total Cost of Ownership

Variable speed fans

Variable speed fans reduce energy consumption during off-peak cooling periods.

In-Row architecture

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Agility

Modular design

Modular design provides scalable solutions to add cooling as demand increases.

Scalable densities

Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.

Serviceability

Easy service access

Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors.

Manageability

Microprocessor controller

Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display.

Building Management System Integration

Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Real-Time Capacity Monitoring

Real-time display of current and available cooling.


To learn more about PTS consulting services to support Air Conditioning Equipment & Systems deployments and support, contact us or visit:


Back to the Top



Loading


Visit PTS on Facebook Follow PTS on Twitter View PTS' YouTube Channel Connect with PTS on LinkedIn Read PTS' Blog
Share
Virtualization Savings Calculator Sign Up for PTS Newsletters Data Center Maintenance Management Software (DCMMS) Rack Management Platform (RaMP) from No Limits Software Considering Data Center Migration? PTS White Paper Library Data Center Education and Training
** SPECIAL **
CFD SERVICES
COMPUTER ROOM
SERVICES
SERVER ROOM &
NETWORK ROOM
SERVICES
DATA CENTER
INDUSTRY LINKS
PTS DATA CENTER PROJECT IMAGE GALLERY
PTS Image Gallery
SUPPORT
1.866.PTS.DCS1
1.866.787.3271
info@ptsdcs.com
PTS Data Center Solutions, Inc. 568 Commerce Street, Franklin Lakes, NJ 07417
Toll Free: 1.866.PTS.DCS1   Tel: 201.337.3833   Fax: 201.337.4722   Email: info@ptsdcs.com
 
Data Center News & Information | Data Center Consulting | Data Center Design & Engineering | Data Center Project Management
Data Center Construction | Data Center Solutions | Data Center Monitoring & Control | Data Center Operations & Maintenance
 
Request Info About Us Contact Us Site Map
© PTS Data Center Solutions, Inc. All rights reserved.