InfraStruxure InRow OA Pumped Refrigerant Data Center Cooling Solutions
closely couple the cooling with the IT heat load. This design
prevents hot air recirculation, while improving cooling
predictability and allowing for a pay as you grow environment.
Available in overhead or floor mounted configurations, these
products are designed to reduce power and whitespace consumption
without introducing chilled water next to IT equipment. Data center
operators looking to improve efficiency or deploy high density
servers will benefit from the modular design of the InRow Pumped
Refrigerant products. The intelligent controls of the InRow Pumped
Refrigerant products actively adjust fan speed and refrigerant flow,
with no minimum loading, to match the IT heat load to maximize
efficiency and address the dynamic demands of today's IT
environments provide high capacity precision air conditioning to
maximize cooling for high efficiency operation.
|
Features
|
Benefits
|
|
Availability
|
|
Predictable cooling
|
Placing the unit in the row of racks moves the source of cooling
closer to the heat load. This
eliminates air mixing and provides a
predictable cooling architecture.
|
|
Dual A-B Power Inputs
|
Draws power from the UPS for power protection with dual feeds for
redundancy.
|
|
Rack Inlet Control
|
Rack inlet control guarantees inlet temperature to IT equipment.
|
|
Active response controls
|
Monitors and actively adjusts cooling capacity to ensure proper
server inlet temperatures. Through
the microprocessor controller,
visibility into the operation and
health of the unit is provided.
|
|
No minimum heat load requirement
|
Cooling system will operate from 0 -
100% of the design capacity.
|
|
Total Cost of Ownership
|
|
Variable speed fans
|
Variable speed fans reduce energy consumption during off-peak
cooling periods.
|
|
In-Row architecture
|
Captures hot exhaust air directly
from the IT equipment, thereby
increasing the unit's sensible
cooling capacity over traditional
cooling architectures.
|
|
Agility
|
|
Modular design
|
Modular design provides scalable solutions to add cooling as
demand increases.
|
|
Scalable densities
|
Allows for higher cooling to be
achieved by integrating the Hot
Aisle Containment System with
row-based architecture.
|
|
Serviceability
|
|
Easy service access
|
Allows for all serviceable components to be replaced / maintained
by easily accessible panels/doors.
|
|
Manageability
|
|
Real-Time Capacity Monitoring
|
Real-time display of current and
available cooling.
|
|
Microprocessor controller
|
Provides proactive control and
real-time monitoring via a four
line, eighty character, alphanumeric
display.
|
|
Building Management System Integration
|
Send alarms and data points allowing
you to manage critical building
infrastructure from a single system.
|